C166. Park KW, Kang SH, Kang HJ, Koo BK, Park BE, Cha KS, Rhew JY, Jeon HK, Shin ES, Oh JH, Jeong MH, Kim S, Hwang KK, Yoon JH, Lee SY, Park TH, Moon KW, Kwon HM, Hur SH, Ryu JK, Lee BR, Park YW, Chae IH, Kim HS; A randomized comparison of platinum chromium-based everolimus-eluting stents versus cobalt chromium-based Zotarolimus-Eluting stents in all-comers receiving percutaneous coronary intervention: HOST-ASSURE (harmonizing optimal strategy for treatment of coronary artery stenosis-safety & effectiveness of drug-eluting stents & anti-platelet regimen), a randomized, controlled, noninferiority trial. J Am Coll Cardiol. 2014;63(25 Pt A)2805-2816.
(Abstract)
OBJECTIVES:
This study sought to test whether the newly developed platinum chromium (PtCr)-based everolimus-eluting stent (EES) is noninferior to the cobalt chromium (CoCr)-based zotarolimus-eluting stent (ZES) in all-comers receiving percutaneous coronary intervention (PCI).
BACKGROUND:
PtCr provides improved radial strength, conformability, and visibility compared with the CoCr alloy, but PtCr-based stents have not been tested in a wide range of patients receiving PCI. Also, recent case series have raised the issue of longitudinal stent deformation (LSD) with newer drug-eluting stents.
METHODS:
We randomly assigned 3,755 all-comers receiving PCI to PtCr-EES or CoCr-ZES. The primary outcome was target lesion failure (TLF) at 1-year post-PCI, defined as the composite of cardiac death, nonfatal target vessel-related myocardial infarction, and ischemia-driven target lesion revascularization. Post-hoc angiographic analysis was performed to qualitatively and quantitatively analyze LSD.
RESULTS:
At 1 year, TLF occurred in 2.9% and 2.9% of the population in the PtCr-EES and CoCr-ZES groups, respectively (superiority p = 0.98, noninferiority p = 0.0247). There were no significant differences in the individual components of TLF as well as the patient-oriented clinical outcome. Of 5,010 stents analyzed, LSD occurred in 0.2% and 0% in the PtCr-EES and CoCr-ZES groups, respectively (p = 0.104). There was no significant difference in post-deployment stent length ratio between the 2 stents (p = 0.352).
CONCLUSIONS:
Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
|